Skip Ribbon Commands
Skip to main content

Conventional Devices

​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​

Die Cast Metal Manual Pull Stations

Silent Knight's new line of manual pull stations feature high-quality, die cast metal construction. They are available in either single or dual action configurations with SPST switch, and with wire lead or terminal strip connections. The normally open contact, which closes when the pull station is activated, is rated for 1 amp, at 125VAC, or 3OVDC. The contacts are gold-plated to avoid risk of corrosion. All models in the series have been tested by UL for compliance to the latest requirements of the Americans with Disabilities Act (ADA).
Silent Knight's new line of manual pull stations feature high-quality, die cast metal construction. They are available in either single or dual action configurations with SPST switch, and with wire lead or terminal strip connections. The normally open contact, which closes when the pull station is activated, is rated for 1 amp, at 125VAC, or 3OVDC. The contacts are gold-plated to avoid risk of corrosion. All models in the series have been tested by UL for compliance to the latest requirements of the Americans with Disabilities Act (ADA).

5230 LCD Remote Annunciator

The Model 5230 Remote Alphanumeric Annunciator can be used to program models 5104, 5204, 5207 and C6000 controls. Programming options include telephone numbers, reporting format, account number, loop response times (electronic retard), test time, output activation, and user and installer codes. System programming is stored in a non-volatile EEPROM chip which is re-programmable hundreds of times. Each control features a quick-connect plug that allows temporary connection of the annunciator for programming.
The Model 5230 Remote Alphanumeric Annunciator can be used to program models 5104, 5204, 5207 and C6000 controls. Programming options include telephone numbers, reporting format, account number, loop response times (electronic retard), test time, output activation, and user and installer codes. System programming is stored in a non-volatile EEPROM chip which is re-programmable hundreds of times. Each control features a quick-connect plug that allows temporary connection of the annunciator for programming.

5217 10-Zone Expander for 5208

The SK-5217 provides the SK-5208 with ten additional Class B (style B) zones. The SK-5217 can be installed in the SK-5208 control cabinet or remotely (up to 1500 ft.) in a SK-2190 accessory cabinet. The SK-5217 communicates to the SK-5208 control panel via a 4-wire connection to the SBUS.
The SK-5217 provides the SK-5208 with ten additional Class B (style B) zones. The SK-5217 can be installed in the SK-5208 control cabinet or remotely (up to 1500 ft.) in a SK-2190 accessory cabinet. The SK-5217 communicates to the SK-5208 control panel via a 4-wire connection to the SBUS.

Single and Dual Action Conventional Pull Stations

The PS-DA/PS-SA Pull Stations are non-coded manual pull stations which provide a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal. The PS-DA/PS-SA pull stations includes both single-action and dual-action models equipped with key lock / reset. It was designed to meet multiple applications with the installer and end-user in mind. Its innovative design, durable construction, and multiple mounting options make the PS-DA and PS-SA simple to install, maintain, and operate.
The PS-DA/PS-SA Pull Stations are non-coded manual pull stations which provide a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal. The PS-DA/PS-SA pull stations includes both single-action and dual-action models equipped with key lock / reset. It was designed to meet multiple applications with the installer and end-user in mind. Its innovative design, durable construction, and multiple mounting options make the PS-DA and PS-SA simple to install, maintain, and operate.

5235 Remote Annunciator for 5208

The SK-5235 remote annunciator provides remote annunciation for the SK-5208 Fire Alarm Control Panel. The SK-5235 performs all system operations. It also provides trouble and alarm information and can be used for programming. The SK-5208 can support up to six 5235 Remote Annunciators.
The SK-5235 remote annunciator provides remote annunciation for the SK-5208 Fire Alarm Control Panel. The SK-5235 performs all system operations. It also provides trouble and alarm information and can be used for programming. The SK-5208 can support up to six 5235 Remote Annunciators.

5280 Status Display Module for 5208

The SK-5280 status display module provides outputs and control functions for remote annunciation of alarm, trouble, and supervisories for each zone.
The SK-5280 status display module provides outputs and control functions for remote annunciation of alarm, trouble, and supervisories for each zone.